Inverter Topologies
Understanding the various inverters and it’s building blocks.
Inverter

Inverter-Charger

Bi-Directional Inverter-Charger

Systems like these can also be configured to feed back into the grid. In case of grid feed applications, S1 will automatically open when the grid falls away to prevent grid-feed and accidental shock.
Hybrid Inverter-Charger

On-Grid Inverters
Hybrid Grid-Tie Inverter-Charger

Bi-Directional Hybrid Inverter-Charger

Grid-Tie Inverter

Model | Inverter (All PSW) |
AC Battery Charger | Storage | Solar | Bi-Directional | Grid-Tie |
APS Micro | Y | N | N | Y | N | Y |
SRM | Y | N | Y | N | N | N |
APC | Y | Y | Y | N | N | N |
HP/HPM | Y | Y | Y | N | N | N |
MultiPlus | Y | Y | Y | N | Y | Y* |
Quattro | Y | Y | Y | N | Y | Y* |
HP-PV | Y | Y | Y | Y | N | N |
Mercer Sol | Y | Y | Y | Y | N | N |
eMax | Y | Y | Y | Y | N | N |
Infini 2-10kW | Y | Y | Y | Y | Y | Y |
Infini Super | Y | Y | Y | Y | Y | Y |
Infini V | Y | Y | Y | Y | Y | Y |
Goodwe EM/ES | Y | Y | Y | Y | Y | Y |
Description
Topology: Inverter-Charger
Features
- High overload ability of up to 300% rated power (20 sec).
- Low quiescent current.
- Selectable power saver mode to reduce power consumption to 10W (3s sensing cycle)/3W (30s sensing cycle).
- Extract maximum power from various batteries with different protections. Low voltage trip can be selected as either 9.5V/10V or 10V/10.5V.
- Uses Power Factor Correction (PFC), which results in lower power consumption than conventional units.
- Automatic Generator Start (AGS) optional.
- 10ms typical transfer time between battery and AC, which guarantees power continuity.
- Uses selectable input AC voltage (184-253V or 154-253V) for different kinds of loads.
- High charge rate of up to 90A, selectable from 0-100%.
- Units utilize 3-step intelligent battery charging equipped with 8 preset battery type selector plus de-sulfurization cycle for totally flat batteries.
- Allows start-up and through power with depleted batteries.
- Battery/AC priority switch for off-grid solar/wind system.
- LCD status display and USB communication port.
- 17 alarms/warnings for easier operation and trouble-shooting.
- Ability to switch the unit on/off.

Model | Power (W) | Battery voltage (V) | Max AC Charge current (A) | L (mm) | W (mm) | H (mm) | Weight (kg) | kW Charging |
APC 1-12 | 1000 | 12 | 35±5A | 382 | 218 | 179 | 16 | 420 |
APC 1.5-24 | 1500 | 24 | 20±5A | 382 | 218 | 179 | 17 | 480 |
APC 2-24 | 2000 | 24 | 30±5A | 442 | 218 | 179 | 20 | 720 |
APC 3-48 | 3000 | 48 | 25±5A | 442 | 218 | 179 | 24 | 1200 |
APC 4-48 | 4000 | 48 | 35±5A | 598 | 218 | 179 | 35 | 1680 |
APC 5-48 | 5000 | 48 | 40±5A | 598 | 218 | 179 | 45 | 1920 |
APC 6-48 | 6000 | 48 | 50±5A | 598 | 218 | 179 | 45 | 2400 |
Description
Topology: Inverter-Charger
Features
- Durable low frequency design.
- Smart remote control.
- High overload capacity 300% (20s).
- Designed to operate under harsh environment.
- DC start & automatic self-diagnostic function.
- Compatible with both linear & non-linear load.
- Easy to install and operate.
- Low DC voltage supports home & office appliances.
- Powerful charge rate up to 100A, selectable from 0%-100%.
- High efficiency design and power saving mode to conserve energy.
- Battery/AC priority switch for off-grid solar/wind system.
- 13 VDC battery recover point, dedicated for renewable energy systems.
- 8 pre-set battery type selector plus de-sulfurization cycle for totally flat batteries.
- 4-step intelligent battery charging, PFC (power factor correction) for charger.
- 8 ms typical transfer time between utility & battery, guarantees power continuity.
- 15s delay before transfer when AC resumes, protection for load when used with generator.

Model | Power (W) | Battery voltage (V) | Max AC Charge current (A) | H (mm) | W (mm) | D (mm) | Weight (kg) | Watt Charging |
HPM 0.6-12 | 600 | 12 | 20±5A | 425 | 230 | 205 | 8.5 | 240 |
HPM 1-12 | 1000 | 12 | 25±5A | 475 | 230 | 205 | 12 | 300 |
HP 1-12 | 1000 | 12 | 30±5A | 388 | 350 | 200 | 21 | 360 |
HP 1.5-24 | 1500 | 24 | 20±5A | 388 | 350 | 200 | 22 | 480 |
HP 2-24 | 2000 | 24 | 25±5A | 388 | 350 | 200 | 23 | 600 |
HP 3-48 | 3000 | 48 | 20±5A | 388 | 350 | 200 | 27 | 960 |
HP 4-48 | 4000 | 48 | 30±5A | 488 | 415 | 200 | 38 | 1440 |
HP 5-48 | 5000 | 48 | 40±5A | 488 | 415 | 200 | 48 | 1920 |
HP 6-48 | 6000 | 48 | 50±5A | 488 | 415 | 200 | 49 | 2400 |
HP 8-48 | 8000 | 48 | 65±5A | 588 | 415 | 200 | 60 | 3120 |
HP 10-48 | 10000 | 48 | 80±5A | 588 | 415 | 200 | 66 | 3840 |
HP 12-48 | 12000 | 48 | 100±5A | 588 | 415 | 200 | 70 | 4800 |
Description
Topology: Bi-Directional Inverter-Charger
Features
- Unique power assist feature: Boosting the capacity of shore or generator power
- PowerControl – Dealing with limited generator, shore side or grid power
- UPS function (transfer in less than 20milli seconds)
- Up to 6 parallel units
- 3 Phase capability
- Onsite and Remote monitoring and control
- Separate battery charger output (4A)
- Operating temperature: -40 to +65°C, Fan assisted cooling, Humidity up to 95% (non condensing)
- Input voltage: 187-265VAC, 45-65Hz
- Programmable relay, Battery Temperature sensor
- VE Bus communication port, Remote on/off,
- IP21, Enclosure Aluminium
Model | Power (W) |
Battery Voltage (V) | Standby Power (W) |
Max AC Charge Current (A) | Auxiliary Output (A) |
Transfer Switch (A) |
Dimentions (H x W x D) (mm) |
Weight (kg) |
MultiPlus 24/3000/70 | 3000 | 24 | 20 | 70 | 16 | 50 | 362 x 258 x 218 | 18 |
MultiPlus 48/3000/35 | 3000 | 48 | 25 | 35 | 16 | 50 | 362 x 258 x 218 | 18 |
MultiPlus 24/5000/120 | 5000 | 24 | 30 | 120 | 25 | 100 | 444 x 328 x 240 | 30 |
MultiPlus 48/5000/70 | 5000 | 48 | 35 | 70 | 25 | 100 | 444 x 328 x 240 | 30 |
Description
Topology: Bi-Directional Inverter-Charger
Features
- Two AC inputs with integrated transfer switch
- Two AC outputs
- Unique power assist feature: Boosting the capacity of shore or generator power
- PowerControl – Dealing with limited generator, shore side or grid power
- UPS function (transfer in less than 20milli seconds)
- Up to 6 parallel units
- 3 Phase capability
- Onsite and Remote monitoring and control
- Separate battery charger output (4A)
- Operating temperature: -40 to +65°C, Fan assisted cooling, Humidity up to 95% (non condensing)
- Input voltage: 187-265VAC, 45-65Hz
- Programmable relay x3, Battery Temperature sensor
- VE Bus communication port for parallel and three-phase operation, remote monitoring and system integration
- General purpose communication port x2
- Remote on/off
- IP21, Enclosure Aluminium
Model | Power (W) |
Battery Voltage (V) | Standby Power (W) |
Max AC Charge Current (A) | Auxiliary Output | Maximum feed-through current (A) | Dimentions (H x W x D) (mm) |
Weight (kg) |
Quattro 48/5000/70-100 | 5000 | 48 | 35 | 70 | 50 | 2x 100 | 444 x 328 x 240 | 30 |
Quattro 48/8000/110-100 | 8000 | 48 | 50 | 110 | 50 | 2x 100 | 470 x 350 x 280 | 41 |
Quattro 48/10000/140-100 | 10000 | 48 | 55 | 140 | 50 | 2x 100 | 470 x 350 x 280 | 45 |
Quattro 48/15000/200-100 | 15000 | 48 | 80 | 200 | 50 | 2x 100 | 572 x 488 x 344 | 72 |
Description
Topology: Hybrid Inverter-Charger
Features
- Pure sine wave inverter.
- High surge capacity of 200% for 5s.
- Peak efficiency of 90%
- Configurable input voltage range for home appliances and personal computers via LCD setting.
- Configurable battery charging current based on applications via LCD setting.
- Configurable AC/Solar Charger priority via LCD setting.• Compatible with mains voltage or generator power.
- Auto restart while AC is recovering.
- Overload/ Over temperature/ short circuit protection.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- Up to six units in parallel or in three phase configuration (5KVA unit only).

eMax Inverter with PWM Charger
Model: PS | Power | Battery voltage | Solar Charger | Charge Voltages | Max AC Charge Current | Max Total Charge Current | Rated Solar Power (W) | Dimensions (H x W x D) (mm) |
Weight (kg) |
eMax 1kVA-12V PS | 0.8kW | 12V | PWM 50A | 40Voc 15-18Vmp | 20A | 50A | 600 | 305 x 300 x 110 | 4.5 |
eMax 3kVA-24V PS | 2.4kW | 24V | PWM 50A | 80Voc 30-32Vmp | 30A | 50A | 1200 | 305 x 272 x 100 | 6.9 |
eMax 3kVA-24V PS PLUS | 3kW | 24V | PWM 50A | 80Voc 30-32Vmp | 30A | 50A | 1200 | ||
eMax 5kVA-48V PS | 4kW | 48V | PWM 50A | 105Voc 60-72VMP | 60A | 110A | 2400 | 413 x 295 x 120 | 9.8 |
eMax Inverter with MPPT Charger
Model: MPS | Power | Battery voltage | Solar Charger | Charger Voltages | Max AC Charge Current | Max Total Charge Current | Rated Solar Power (W) | Dimensions (H x W x D) (mm) |
Weight (kg) |
eMax 1kVA-24V MPS | 800W | 24V | MPPT 25A | 75Voc, 30-66Vmp | 20A | 25A | 600 | 355 x 272 x 128 | 7.4 |
eMax 3kVA-24V MPS | 2.4kW | 24V | MPPT 60A | 145Voc, 60-115Vmp | 30A | 60A | 1500 | 355 x 272 x 128 | 10 |
eMax 3.2kVA-24V MPS V | 3.2kW | 24V | MPPT 80A | 500Voc, 120-450Vmp | 80A | 80A | 4000 | ||
eMax 5kVA-48V MPS * | 4kW | 48V | MPPT 60A | 145Voc, 60-115Vmp | 60A | 120A | 3000 | 540 x 295 x 140 | 13.5 |
eMax 5kVA-48V MPS PLUS * | 5kW | 48V | MPPT 80A | 145Voc, 60-115Vmp | 60A | 140A | 4000 | ||
eMax 5kVA-48V MPS V | 5kW | 48V | MPPT 80A | 500Voc, 120-450Vmp | 60A | 80A | 4000 | 541 x 295 x 140 | 14.5 |
Description
This is a high quality multi-function inverter/charger, combining the functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power supply. The comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
All the inverters in the eMax+ range has RS485 BMS communication and WiF monitoring, which make it the perfect inverter to use with Pylon Lithium Ion Bateries.
Topology: Hybrid Inverter-Charger
Features
- Rated power 2kW ~ 5kW, Power Factor 1
- Built-in MPPT charge controller with either low voltage DC input (MHP), or high voltage DC input (BC)
- High frequency inverter with compact design
- Pure sine wave AC output
- Configurable AC/solar input priority via LCD settings
- Parallel option up to 6 units (optional on 4kW and 5kW LV models only)
- WiFi remote monitoring (standard)
- GPRS functionality (optional)
- RS485 communication for BMS (standard)

eMax+ MHP Low Voltage MPPT
Stock Code | Model: eMax+ MHP Low Voltage MPPT |
Power | Battery voltage | Solar Charger | Charger Voltages | Max AC Charge Current | Max Total Charge Current | Rated Solar Power (W) | Dimensions (H x W x D) (mm) |
Weight (kg) |
IHEMPMHP2K | eMax+, 2kVA, LV | 2kW | 24V | MPPT 50A | 102Voc, 30-80Vmp | 30A | 1500W | 385 x 280 x 130 | 7kg | |
IHEMPMHP3K | eMax+, 3kVA, LV | 3kW | 24V | MPPT 50A | 102Voc, 30-80Vmp | 30A | 1500W | 385 x 280 x 130 | 7.5kg | |
IHEMPMHP4K | eMax+, 4kVA, LV, Parallel | 4kW | 48V | MPPT 80A | 145Voc, 60-115Vmp | 60A | 4500W | 455 x 295 x 130 | 11kg | |
IHEMPMHP5K | eMax+, 5kVA, LV, Parallel | 5kW | 48V | MPPT 80A | 145Voc, 60-115Vmp | 60A | 4500W | 455 x 295 x 130 | 11.5kg |
eMax+ BC High Voltage MPPT
Stock Code | Model: eMax+ BC High Voltage MPPT |
Power | Battery voltage | Solar Charger | Charger Voltages | Max AC Charge Current | Max Total Charge Current | Rated Solar Power (W) | Dimensions (H x W x D) (mm) |
Weight (kg) |
IHEMPBC3K | eMax+, 3kVA, HV | 3kW | 24V | MPPT 100A | 120-430Vdc | 80A | 100A | 3500W | 470 x 320 x 135 | 12kg |
IHEMPBC5K | eMax+, 5kVA, HV | 5kW | 48V | MPPT 100A | 120-430Vdc | 80A | 100A | 5500W | 470 x 320 x 135 | 12kg |
eMax+ Extras
Stock Code | eMax+ Extras | Dimensions (H x W x D) (mm) |
Weight (kg) |
IHEMPWIFI | Cube Wifi | 135 x 79 x 29 | 63g |
IHEMPGPRS | Cube GPRS | 135 x 79 x 29 | 70g |
IHEMPH01 | CAN/RS485 hub for parallel connection |

Description
Topology: Hybrid Inverter-Charger
Features
- Pure sine wave inverter.
- High surge capacity of 200% for 5s.
- Configurable input voltage range for home appliances and personal computers via LCD setting.
- Configurable battery charging current based on applications via LCD setting.
- Configurable AC/Solar Charger priority via LCD setting.
- Compatible with mains voltage or generator power.
- Auto restart while AC is recovering.
- Overload/ Over temperature/ short circuit protection.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- 5M Up to 6 Units in parallel, 5P up to 9 units in parallel.
- 15s delay before transfer when AC resumes, protection for load when used with generator.

Model | Power (kW) | Battery voltage (V) | Solar Charger | Charger Voltages | Max AC Charge current (A) | Max Total charge current (A) | Rated Solar Power (W) | Dimensions (H x W x D) (mm) |
Weight (kg) |
SOL-I-AX-1.5MEX-12 | 1.2kW | 12 | MPPT 40A | 75Voc, 30-66Vmp | 60 | 100 | 500 | 355 x 272 x 100 | 7 |
SOL-I-AX-3M-24 | 3.0kW | 24 | MPPT 25A | 600 | |||||
SOL-I-AX-3MPlus24 | 2.4kW | 24 | MPPT 60A | 1500 | |||||
SOL-I-AX-3MPlus48 | 3.0kW | 48 | MPPT 60A | 145Voc, 60-115Vmp | 15 | 60 | 3000 | 479 x 295 x 140 | 11.5 |
SOL-I-AX-5P | 5kW | 48 | MPPT 80A | 145Voc, 60-115Vmp | 60 | 140 | 4000 | 468 x 295 x 120 | 13.5 |
SOL-I-AX-5D | 5kW | 48 | 2x MPPT 60A | 145Voc, 60-115Vmp | 6000 | ||||
SOL-I-AX-5T | 5kW | 48 | 3x MPPT 60A | 145Voc, 60-115Vmp | 9000 | ||||
SOL-I-AX-5II | 5kW | 48 | MPPT 80A | 450Voc, 120-430Vmp | 80 | 80 | 4500 | ||
Remote Display | |||||||||
Parallel Comms Card | |||||||||
Web Box for AX Series |
Description
High-quality, high efficiency PSW inverter + AC charger + MPPT solar charger with a ultra low Total Harmonic Distortion (THD) of only 7% under full linear loads. Connected to batteries the inverter functions as a UPS with transfer times of <10ms. The transformers of this top line inverters are designed to comply with UL and efficiency of ±90%.
Topology: Hybrid Inverter-Charger
Features
- Durable low frequency design.
- Smart remote control.
- High overload capacity 300% (20s).
- Designed to operate under harsh environment.
- DC start & automatic self-diagnostic function.
- Compatible with both linear & non-linear load.
- Easy to install and operate.
- Low DC voltage supports home & office appliances.
- Powerful charge rate up to 100A, selectable from 0%-100%.
- High efficiency design and power saving mode to conserve energy.
- Battery/AC priority switch for off-grid solar/wind system.
- 13 VDC battery recover point, dedicated for renewable energy systems.
- 8 pre-set battery type selector plus de-sulfurization cycle for totally flat batteries.
- 4-step intelligent battery charging, PFC (power factor correction) for charger.
- 8 ms typical transfer time between utility & battery, guarantees power continuity.
- 15s delay before transfer when AC resumes, protection for load when used with generator.
Model | Power (W) | Battery voltage (V) | Solar Charger | Charger Voltages | Max AC Charge current (A) | Max Total charge current (A) | Rated Solar Power (W) | H (mm) | W (mm) | D (mm) | Weight (kg) |
HP-PV 1-12 | 1000 | 12 | MPPT 60A | 45Voc, 15-45Vmp |
30±5A | 90 | 720 | 388 | 415 | 200 | 23.5 |
HP-PV 1.5-24 | 1500 | 24 | MPPT 40A | 70Voc, 30-70Vmp |
20±5A | 60 | 1000 | 388 | 415 | 200 | 24.5 |
HP-PV 2-24 | 2000 | 24 | MPPT 40A | 70Voc, 30-70Vmp |
25±5A | 65 | 1000 | 388 | 415 | 200 | 25.5 |
HP-PV 3-48 | 3000 | 48 | MPPT 40A | 100Voc, 60-100Vmp |
20±5A | 60 | 2000 | 388 | 415 | 200 | 29.5 |
HP-PV 4-48 | 4000 | 48 | MPPT 40A | 100Voc, 60-100Vmp |
30±5A | 70 | 2000 | 488 | 415 | 200 | 40.5 |
HP-PV 5-48 | 5000 | 48 | MPPT 80A | 100Voc, 60-100Vmp |
40±5A | 120 | 4000 | 488 | 415 | 200 | 53 |
HP-PV 6-48 | 6000 | 48 | MPPT 80A | 100Voc, 60-100Vmp |
50±5A | 130 | 4000 | 488 | 415 | 200 | 54 |
HP-PV 8-48 | 8000 | 48 | MPPT 80A | 100Voc, 60-100Vmp |
65±5A | 145 | 4000 | 588 | 415 | 200 | 65 |
HP-PV 10-48 | 10000 | 48 | MPPT 80A | 100Voc, 60-100Vmp |
80±5A | 160 | 4000 | 588 | 415 | 200 | 71 |
HP-PV 12-48 | 12000 | 48 | MPPT 80A | 100Voc, 60-100Vmp |
100±5A | 180 | 4000 | 588 | 415 | 200 | 75 |
Description
Topology: Bi-Directional Hybrid Inverter-Charger
Features
- Pure sine wave output
- Self-consumption and Feed-in to the grid
- Programmable supply priority for PV, Battery or Grid
- User-adjustable battery charging current suits different types of batteries
- Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
- Built-in timer for various mode of on/off operation
- Multiple communication for USB, RS-232, Modbus and SNMP
- Monitoring software for real-time status display and control
- Parallel operation up to 6 units for 5KW and 10KW

Stock Code | Model | Power (kW) | Battery voltage (V) | Max PV Input Power | Charger Voltages | Max AC Charge Power | Max Total charge current (A) | Grid Feed Output | Dimensions (D x W x H) (mm) |
Weight (kg) |
IHIIS3M | Infini 3K Plus | 3kW | 48 | MPPT 4.5kW | 500Voc, 250-450Vmp | 1200W | 25A | 13A | 107 x 438 x 480 | 15.5 |
IHIIS5M | Infini 5kW | 5kW | 48 | MPPT 10kW | 900Voc, 250-850Vmp | 4800W | 100A | 21A | 204 x 460 600 | 29 |
IHIIS10M | Infini 10K 3Phase | 10kW | 48 | MPPT 15kW | 900Voc, 400-800Vmp | 9600W | 200A | 14.5Aⁱ | 167 x 500 x 622 | 45 |
Description
Topology: Hybrid Grid-Tie Inverter-Charger
Features
- Pure Sinewave output
- Self-consumption and Feed-in to the grid
- Programmable supply priority for PV, Battery or Grid
- User-adjustable battery charging current suits different types of batteries
- Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
- Accept dual AC inputs: Utility and Generator compatible
- Built-in emergent power supply port for emergent lighting or loads
- Multiple communication for USB, Modbus and SNMP
- Monitoring software for real-time status display and control
- Parallel operation up to 6 units
- Enhanced AC/Solar charger to 80A

Stock Code | Model | Power (kW) | Battery voltage (V) | Max PV Input Power | Charger Voltages | Max AC Charge Power | Max Total charge current (A) | Grid Feed Output | Dimensions (D x W x H) (mm) |
Weight (kg) |
IHIS4K | Infini Super 4Kw | 4kW | 48V | MPPT 5kW | 580Voc, 280-500Vmp | 40A | 80A | 17.5A | 117 x 438 x 535 | 16.2 |
Description
Topology: Hybrid Grid-Tie Inverter-Charger
Features
- Pure sine wave output
- Self-consumption and Feed-in to the grid
- Programmable supply priority for PV, Battery or Grid
- User-adjustable battery charging current and voltage
- Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
- Monitoring software for real-time status display and control
- Parallel operation up to 6 units only for 3K/4K/5K models

Stock Code | Model | Power (kW) | Battery voltage (V) | Max PV Input Power | Charger Voltages | Max AC Charge Current | Max Total Charge Current | Grid Feed Output | Dimensions (D x W x H) (mm) |
Weight (kg) |
IHIV1K12 | Infini V-1K-12 | 1kW | 12V | 1000W | 145Voc, 15-115Vmp | 60A | 140A | 4.3A | 100 x 300 x 440 | 8 |
IHIV2K24 | Infini V-2K-24 | 2kW | 24V | 2000W | 145Voc, 30-115Vmp | 60A | 140A | 8.7A | 100 x 300 x 440 | 8 |
IHIV3K48 | Infini V-3K-48 | 3kW | 48V | 4000W | 145Voc, 60-115Vmp | 60A | 140A | 13A | 120 x 295 x 468 | 11 |
IHIV4K48 | Infini V-4K-48 | 4kW | 48V | 4000W | 145Voc, 60-115Vmp | 60A | 140A | 17.4A | 120 x 295 x 468 | 11 |
IHIV5K48 | Infini V-5K-48 | 5kW | 48V | 6kW-Dual MPPT | 145Voc, 60-115Vmp | 60A | 180A | 21.7A | 190 x 295 x 483 | 16 |
Description
Topology: Bi-Directional Hybrid Inverter-Charger
Features
- Charge controller and inverter integrated
- Intelligent battery management function
- Longer service life than conventional system
- Capable of being grid-interactive or grid-independent\
- Compatible with both Lead-acid and Lithium-Ion battery
- More security and performance for same cost
- Monitor inverter locally via EzMonitor
- Monitor inverters freely via computers or smart phone\
- Fanless, low noise design
- IP65 dust proof and water-proof rating
- 45 Deg C full load output

Technical Specifications of the EM Series
- Dual MPPT trackers (not available on GW3048-EM)
- DC Connector: Amphenol/MC4/Sunclix
- Charging curve: 3 Stage adaptive with maintenance
- Battery temperature compensation for Lithium
- Integrated battery voltage sensing
- Integrated current shunt
- Peak output apparent power: 3500VA for 10 sec
- 50/60Hz, 230VAC
- THDi<1.5%
- Automatic switch time: 10ms
- Power factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)
- Single phase grid connection
- Efficiency: 97,6%, Battery to load: 94.5%
- Protection: Anti-islanding, PV string reverse polarity, Insulation resistor detection, residual current monitoring, output over-current, output short circuit, Output over-voltage
- Wall bracket mounting
- -25 to 60DegC ambient temperature range
- Standby losses < 13W
- Communication: RS458, CanBus, WiFi
- Standard Warranty: 5 Years
Technical Specifications of the ES Series
- Dual MPPT trackers
- DC Connector: Amphenol/MC4/Sunclix
- Charging curve: 3 Stage adaptive with maintenance
- Battery temperature compensation for Lithium
- Integrated battery voltage sensing
- Integrated current shunt
- 150% peak power for 10sec
- 50/60Hz, 230VAC
- THDi<1.5%
- Power factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)
- Single phase grid connection
- 97.6% efficiency
- Protection: Residual current monitoring, Anti-islanding, Optional DC PV switch, AC over current, Insulation monitoring
- Wall bracket mounting
- -25 to 60DegC ambient temperature range
- Standby losses < 8W
- Communication through USB2 or WiFi
- Standard Warranty: 5 Years
Model | Power (kW) AC Output/ AC Backup |
Battery voltage (V) | Max PV Input Power-Number of MPPT Controller | Charger Voltages | Max AC Charge Current | Max Total Charge Power | Grid Feed Output | Dimensions (W x H x D) (mm) |
Weight (kg) |
GW3048D-EM | 3kW/ 2.3kW | 48 | 3.9kW-Single | 550Voc, 100-500Vmp | 50A | 2.5kW | 13.6A | 347 x 432 x 175 | 16 |
GW3648D-EM | 3.6kW/ 2.3kW | 48 | 4.6kW-Dual | 550Voc, 100-500Vmp | 50A | 2.5kW | 16A | 347 x 432 x 175 | 17 |
GW5048D-EM | 5kW/2.3kW | 48 | 6.5kW-Dual | 550Voc, 100-500Vmp | 50A | 2.5kW | 22.8A | 347 x 432 x 175 | 17 |
GW3648D-ES | 3.6kW/ 3.6kW | 48 | 4.2kW-Dual | 580Voc, 125-550Vmp | 100A | 5kW | 16.4A | 516 x 420 x 150 | 30 |
GW5048D-ES | 4.6kW/4.6kW | 48 | 5.4kW-Dual | 580Voc, 125-550Vmp | 100A | 5kW | 21A | 516 x 420 x 150 | 30 |
Disclaimer
Colors may vary
Errors and omissions excepted
Prices published does not constitute a final quotation